Cutting fluid – Grizzly Slow Speed Cold Cut G0665 User Manual

Page 24

Advertising
background image

-22-

G0665 Slow Speed Cold Cut Saw

7. Place the blade and flange over the arbor,

then thread and tighten the left-hand thread
arbor cap screw (

Figure 32).

Figure 32. Tightening blade.

8. Lower the blade guide and reconnect the

blade guard linkage with the cap screw.

Cutting Fluid

Tools Needed:

Qty

Hex Wrench 5mm .............................................. 1

Filling the cutting fluid reservoir:

1. DISCONNECT SAW FROM POWER!

2. Remove the cap screws and washers from

the cutting fluid reservoir (

Figure 33).

Draining/cleaning the cutting fluid

reservoir:

1. DISCONNECT SAW FROM POWER!

2. Wearing protective equipment, drain and dis-

pose the cutting fluid following government-
approved disposal regulations for your area.

3. Use a rag to wipe out residual fluid.

4. Clean the cutting fluid screens in the machine

base and the tank.

Used cutting fluid pres-

ents a poison hazard.

Use personal protection

when handling this mate-

rial. Failure to do so may

result in illness or death.

3. Slide the tray out from the machine base.

4. Wearing protective equipment, fill the reser-

voir with a suitable, water-based cutting fluid.
Refer to the manufacturer's specifications for
the proper water/oil mix.

5. Slide the tray back into the base and replace

the cap screws and washers.

Arbor Cap Screw

Blade Guard Linkage

Tighten

Figure 33. Opening cutting fluid reservoir.

Cap Screws

Cutting Fluid Reservoir

Figure 34. Opening cutting fluid reservoir.

Cutting Fluid Screens

Advertising