symptom

possible Cause

possible solution

Machine

does

not start/indica-
tor light does not
come on or a
breaker trips.

1. switch cover not not open.
2. plug/receptacle is at fault or wired incorrectly.
3. Wall fuse/circuit breaker is blown/tripped.

4. indicator light has failed.
5. Control box fuse/s blown.
6. power supply switched oFF or is at fault.

7. Wiring is open/has high resistance.

8. Motor on/oFF switch is at fault.
9. Motor is at fault.

1. reset swtich by opening cover.
2. test for good contacts; correct the wiring.
3. ensure circuit size is suitable for this machine;

replace weak breaker.

4. replace light.
5. Check l1 & l2 fuses in control box.
6. ensure power supply is switched

ON; ensure power

supply has the correct voltage.

7. Check for broken wires or disconnected/corroded

connections, and repair/replace as necessary.

8. replace faulty on/oFF switch.
9. test/repair/replace.

Machine stalls or
is overloaded.

1. Feed pressure too great for task.
2. Motor connection is wired incorrectly.
3. plug/receptacle is at fault.
4. Motor is at fault.

1. decrease feed pressure.
2. Correct motor wiring connections.
3. test for good contacts; correct the wiring.
4. test/repair/replace.

Machine

has

vibration or noisy
operation.

1. Motor or component is loose.

2. Motor mount loose/broken.
3. Machine is incorrectly mounted or sits uneven-

ly.

4 Motor fan is rubbing on fan cover.

5. Motor bearings are at fault.

1. inspect/replace stripped or damaged bolts/nuts, and

re-tighten with thread locking fluid.

2. tighten/replace.
3. tighten/replace anchor studs in floor; relocate/shim

machine.

4. replace dented fan cover; replace loose/damaged

fan.

5. test by rotating shaft; rotational grinding/loose shaft

requires bearing replacement.

indicator light is
on and trigger
switch fails to
activate motor.

1. plug connecting switch to control box is

unplugged.

2. trigger switch at fault.
3. Motor is at fault.

1. Correctly insert plug.

2. test/repair/replace.
3. test/repair/replace.