FUNCTION TESTS

Test Machine Functions

24 Press down the foot switch.

25 Activate each machine function control handle

or toggle switch.

Result: All boom/platform functions should

operate through a full cycle.

Machines equipped with Platform Level Control
Disable Function: The platform level toggle switch
will not operate when the primary boom is raised
past the drive speed limit switch.

Test the Steering

26 Press down the foot switch.

27 Press the thumb rocker switch on top of the

drive control handle in the direction indicated by
the blue triangle on the control panel OR slowly
move the control handle in the direction
indicated by the blue triangle.

Result: The steer wheels should turn in the

direction that the blue triangles point on the
drive chassis.

28 Press the thumb rocker switch on top of the

drive control handle in the direction indicated by
the yellow triangle on the control panel OR
slowly move the control handle in the direction
indicated by the yellow triangle.

Result: The steer wheels should turn in the

direction that the yellow triangles point on the
drive chassis.

At the Platform Controls

Test Emergency Stop

15 Turn the key switch to platform control and

restart the engine.

16 Push in the platform red Emergency Stop

button to the off position.

Result: The engine will shut off after 2 or 3

seconds.

17 Pull out the red Emergency Stop button and

restart the engine.

Test the Horn

18 Push the horn button.

Result: The horn should sound.

Test the Foot Switch

19 Push in the platform red Emergency Stop button

to the off position.

20 Pull out the red Emergency Stop button to

the on position but do not start the engine.

21 Press down the foot switch and attempt to start

the engine by moving the start toggle switch to
either side.

Result: The engine should not start.

22 Do not press down the foot switch and restart

the engine.

Result: The engine should start.

23 Do not press down the foot switch and test each

machine function.

Result: The machine functions should not

operate.