Electrocution hazards, Tip-over hazards – Genie Z-45 User Manual

Page 4

Advertising
background image

2

Genie Z-45/25 & Genie Z-45/25J

Part No. 82600

Operator's Manual

Second Edition · Second Printing

SAFETY RULES

Electrocution Hazards

This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.

Maintain safe distances from electrical power lines
and apparatus in accordance with applicable
governmental regulations and the following chart.

Voltage

Minimum Safe

Phase to Phase

Approach Distance
Feet

Meters

0 to 300V

Avoid Contact

300V to 50KV

10

3.1

50KV to 200KV

15

4.6

200KV to 350KV

20

6.1

350KV to 500KV

25

7.6

500KV to 750KV

35

10.7

750KV to 1000KV

45

13.7

Allow for platform movement, electrical line sway or
sag and beware of strong or gusty winds.

Keep away from the machine if it contacts
energized power lines. Personnel on the ground or
in the platform must not touch or operate the
machine until energized power lines are shut off.

Do not use the machine as a ground for welding.

Do not operate the machine during lightning or
storms.

Tip-over Hazards

Occupants, equipment and materials shall not
exceed the maximum platform capacity.

Maximum platform capacity

500 lbs

227 kg

Maximum occupants

2

Do not raise or extend the boom unless the
machine is on a firm, level surface.

Do not depend on the tilt alarm as a level indicator.
The tilt alarm sounds in the platform only when the
machine is on a severe slope.

If the tilt alarm sounds:
Do not extend, rotate or raise the boom above
horizontal. Move the machine to a firm, level
surface before raising the platform. If the tilt alarm
sounds when the platform is raised, use extreme
caution to retract the boom and lower the platform.
Do not rotate the boom while lowering. Move the
machine to a firm, level surface before raising the
platform.

Do not use the platform controls to free a platform
that is caught, snagged or otherwise prevented
from normal motion by an adjacent structure. All
personnel must be removed from the platform
before attempting to free the platform using the
ground controls.

Do not alter or disable the limit switches.