background image

g0605X1-6X1, g0696X-97X (mfg. 8/11+)

-13-

voltage conversion

Ground

V1

U1

Z1

Y1

X1

V2

U2

W1 W2

Figure 7. motor rewired to 440v.

5. remove the magnetic switch cover and move

the fuse on the fuse block from the 220v
slot to the 440v slot, as shown in

Figure 8.

(Additionanally, refer to the photos on

page

80 and wiring diagram on page 82 for futher
details.

440V

220V

Figure 8. Fuse moved from 220v to 440v slot.

440v Fuse

location

relay dial

7. re-install the magnetic switch cover and

close and secure the motor cover.

6. turn the thermal overload relay dial from 22

amps to 11 amps, as shown in

Figure 9.

RESET

96

98

3/4

5/6

11

22

OFF

W/6/T3

V/4/T2

NO14

95

SDE RA-30

B

Figure 9. overload relay dial turned to 11 amp

setting.

4. rewire the motor, as shown in Figure 7,

tighten the hex nuts, then re-install the junc-
tion box cover.

the model g0606X1/g0697X can be converted
for 440v operation.

this conversion job consists of disconnecting the
saw from the power source, rewiring the motor,
switching the transformer fuse from 220v to 440v,
and changing the thermal overload relay from 22
to 11 Amps.

NOTICE

Refer to the motor junction box cover dia-

gram for motor connection locations and

voltage conversion. If not present, use the

instructions below, or call our Tech Support

Department at (570) 546-9663.

converting Model G0606X1/G0697X

to 440v

1. disConnECt sAW From poWEr!

2. open the motor cover, remove the motor

junction box cover, then loosen the hex nuts
shown in

Figure 6.

3. remove the two jumpers (they are stacked

together), as indicated in

Figure 6.

Ground

Z1 Y1 X1

W1

W2

V1

V2

U1

U2

Figure 6. motor rewired to 440v.

loosen

these hex

nuts

Jumpers

Advertising