L15-30 plug (as recommended), Angle sensor digital readout fuse, Power junction box – Grizzly G0696X User Manual

Page 2: Angle sensor digital readout, On/off switch magnetic switch assembly mpe-30, Motor 440v 3-ph, Phase converter, Parts changes, 220 vac

Advertising
background image

Copyright © NoVEMBEr, 2011 By grizzly iNdustrial, iNC.

Warning: no portion of this manual may be reproduced in any shape

or form Without the Written approval of grizzly industrial, inc.

#KN14523 priNtEd iN taiWaN

We recently made the following changes to this machine and its manual:

Changed the motor from a 9-wire to a 12-wire version.

updated the wiring diagram for the new motor.

aside from the information contained in this update, all other content in the owner's manual applies to this
machine. For your own safety, you Must read and understand this update and the applicable owner's
manual.

Keep this update for future reference!

If you have any further questions about this manual update or the changes made to the machine, contact
our Technical Support at (570) 546-9663 or email [email protected].

model g0606X1/g0697X

***IMPORTANT UPDATE***

applies to models mfg. since 9/11

and owner's manual July, 2010

revised motor 220v 3-phase Wiring

revised motor 440v 3-phase Wiring

R/1/L1

T/5/L3

NO13

S/3/L2

NC15

U/2/T1

W/6/T3

220V

V/4/T2

NC16

NO14

95

A

SDE

MA-30

Ground

1/2

3/4

5/6

11

22

RESET

OFF

SDE RA-30

96

98

B

440V

Ground

Hot

Hot

Hot

L15-30 PLUG

(as recommended)

220 VAC

OFF

ON

14

24

23

13

Angle Sensor

Digital Readout

Fuse

AC2

R18

AC1

On/Off Switch

Magnetic

Switch

Assembly

MPE-30

Motor 220V 3-Ph

If connecting machine to a phase
converter, the manufactured leg
must be connected to terminal L3.

PHASE CONVERTER

Power Junction Box

Installation work and electrical wiring
must be done by qualified electrician in
accordance with all applicable codes
and standards.

Ground

V2

U2

W2

W5

W1

V6

U6

W6

U5

V1

V5

U1

220V

R/1/L1

T/5/L3

NO13

S/3/L2

NC15

U/2/T1

W/6/T3

220V

V/4/T2

NC16

NO14

A

SDE

MA-30

Ground

RESET

96

98

1/2

3/4

5/6

11

22

OFF

95

SDE RA-30

B

220V

OFF

ON

14

24

23

13

Angle Sensor

Digital Readout

AC2

R18

AC1

On/Off Switch

Magnetic

Switch

Assembly

MPE-30

Ground

Hot

Hot

Hot

DISCONNECT

SWITCH

(as recommended)

3-PHASE

440 VAC

Power Junction Box

Installation work and electrical wiring
must be done by qualified electrician in
accordance with all applicable codes
and standards.

440V

Motor 440V 3-Ph

Ground

V2 U2

W2

V6

W1

V1

U6

U1

W6

V5

U5

W5

parts changes

REF PART #

DESCRIPTION

6V2

P0606X1006V2

MOTOR 7-1/2 HP 220V/440V 3-PH V2.11.11

6V2-1 P0606X1006V2-1 MOTOR FAN COVER
6V2-2 P0606X1006V2-2 MOTOR FAN
6V2-3 P0606X1006V2-3 WIRING JUNCTION BOX

6V2

6V2-2

6V2-1

6V2-3

Advertising
This manual is related to the following products: