Section 8: service, Troubleshooting – Grizzly G0696X User Manual

Page 65

Advertising
background image

-62-

g0605X1-6X1, g0696X-97X (mfg. 8/11+)

Troubleshooting

troubleshooting

symptom

possible Cause

possible solution

motor does not
start.

1. switch disabling lock installed.
2. motor connection wired incorrectly.

3. Contactor not energized/has poor contacts.

4. Break or short in wiring; or loose

connections.

5. power supply switched off/has incorrect

voltage.

6. thermal overload relay in mag switch

tripped.

7. start capacitor has blown (g0605X1/

g0696X only).

8. Centrifugal switch at fault (g0605X1/

g0696X only).

9. machine wired out of phase (g0606X1/

g0697X only).

10. phase converter (if used) wild wire connected

wrong (g0606X1/g0697X only).

1. remove switch disabling lock.
2. Wire motor correctly (refer to inside junction box

cover or manual).

3. test all legs for power, test field coil and replace if at

fault.

4. trace/replace broken or corroded wires; fix loose

connections.

5. switch power supply on/verify voltage.

6. Allow relay/motor to cool. if necessary, press reset

button inside switch.

7. test/replace if at fault.

8. Adjust/replace centrifugal switch.

9. swap two power incoming power leads (see

page

12).

10. Connect wild wire to line without transformer or

sensitive electronics.

machine operates in
reverse.

1. power connections wired out of phase

(g0606X1/g0697X only).

1. swap two incoming power leads (see

page 12).

machine

has

excessive vibration
or noise.

1. slight blade wobble.
2. Arbor nut is loose/obstructed by debris.
3. Arbor pulley loose.

4. loose tilt handwheel.
5. Casting at fault.

6. motor fan rubbing on fan cover.

7. motor mounting loose.

8. Belt worn or damaged.
9. Belt(s) slapping cover.
10. pulley loose or not in alignment; shaft bent.
11. machine incorrectly mounted on floor.

12. Arbor bearings at fault.
13. motor bearings worn or damaged.

1. Use a blade stabilizer.
2. remove and clean, then tighten arbor nut.
3. retighten/replace arbor pulley with shaft and thread

locking liquid.

4. tighten the tilt handwheel lock knob.
5. trunnion/geared bearing housing is loose or cracked;

tighten or replace.

6. Fix/replace fan cover; replace loose or damaged

fan.

7. tighten mounting bolts/nuts; use thread locking

fluid.

8. replace belt (see

page 76).

9. tighten belt(s).
10. replace worn pulley, key, and shaft, and realign.
11. level/shim base; tighten/adjust mounting hardware

or feet.

12. replace arbor housing bearings; replace arbor.
13. replace motor bearings or replace motor.

SEcTION 8: SERvIcE

Review the troubleshooting and procedures in this section if a problem develops with your machine. If you
need replacement parts or additional help with a procedure, call our Technical Support at (570) 546-9663.

Note: Please gather the serial number and manufacture date of your machine before calling.

Advertising