GE A8950CC User Manual

Page 42

Advertising
background image

• Closed: If the contact closure is closed then the plunger of the switch is lowered.

Please refer to the Video Input Mapping Menu described earlier for important notes
regarding channel mapping and instructions on how to enable mappings. However, note
that contact signals are mapped as pairs since there are 8 contact channels per
Contact Closure Module.

Main -> Local -> Contacts -> Output Mapping:

This screen allows you to select which optic port is being reviewed for each of the 32
contact output channels. The number under the circuit icon (in the middle of the screen)
indicates which contact channels are selected. The letters under the switch icons to the
left and right indicate at which optic port the selected output channels will be looking.
Arrows to the left and right of the circuit icon indicate that the mapping is enabled. If the
output channels are not mapped to a fiber then the corresponding arrow is not shown.
The status of the output contacts are depicted on the circuits in the middle icon:

• Open: If the contact closure is open then the circuit is open, as shown above.
• Closed: If the contact closure is closed then the circuit is closed.

Please refer to the Video Output Mapping Menu described earlier for important notes
regarding channel mapping and instructions on how to enable mappings. However, note
that contact signals are mapped as pairs since there are 8 contact channels per Contact
Closure Module.

Main -> Local -> Contacts -> Configure:

This menu allows the user to change the format or test a specified contact channel. Use
"+" and "-" to change selections at each line in the menu. Press "left" to exit this screen.
The top line of this menu shows the currently selected channel. The second line,
"1. Style" shows the current contact format:

• Momentary: Configures the selected input channel to behave like a momentary switch.
• Latched: Configures the selected input channel to toggle each time the contact closes.

Contact:

Exit

1, 2

A

A

B

B

Contact:

Exit

1, 2

A

A

B

B

Contact Config 1
1. Style Momentary
2. Type Transmitted
3. Force None

Contact:

Exit

1, 2

1

A

B

1

40

Advertising