Multi Tech Equipment MTA128ST User Manual

Page 31

Advertising
background image

AT Command, S-Registers, and Result Codes

31

Answering Manually

If your communication program is in terminal mode when the

RING

result code appears on your monitor,

you can manually answer the call by typing

ATA <

cr

>

.

Answering Automatically

To cause the MTA128ST/NT to automatically answer a call:

1. Enable autoanswer by setting register

S0

to the ring on which you want the TAto answer (e.g., in

terminal mode, type

S0=4

to make the TA answer on the fourth ring). You also can use either of the

configuration utilities to the turn on autoanswer and set the number of rings.

2. Make sure that the TA is offline.

The TA answers the call after the number of rings specified by

S0

.To disable autoanswer, use a configuration utility or

the command

S0=0.

Note:

If the user wants to accept calls while DTR is low, the TA must be configured to ignore DTR. To do this, enter

AT&D0<cr>. With this configuration, the TA can accept calls while DTR is low. If this configuration setting is not
made, the TA rejects incoming calls until DTR is high while calls comes in.

Hanging Up

To hang up a call, escape to online command mode (

+++AT<

cr

>),

then enter the

H

command

(

ATH<

cr

>).

The escape sequence and hang up command can be combined into one command string:

+++ATH<

cr

>.

Advertising