4 positioning with digital inputs, 1 additional connections 4-11, Point table positioning 4 - 11 – MITSUBISHI ELECTRIC MR-J3-T User Manual

Page 19: With digital inputs 4 - 11, 4positioning with digital inputs, 1 additional connections

Advertising
background image

4

Positioning with Digital Inputs

This chapter describes how point table positioning is used in most applications with the MR-J3-T
series amplifiers and the MR-J3-D01 I/O extension.

NOTE

Please refer to the instruction manual if you need other functions other than those described
here for your application.

4.1

Additional Connections

The initial functional tests described in chapter 3.1 were performed with a minimum connection
configuration. For the full range of standard functions you now need to make additional power
supply and control terminal connections on the CN6 and CN10 terminal blocks, as shown below
in Figs. 4-1 and 4-2.

Positioning with Digital Inputs

Additional Connections

MR-J3-T

4 - 11

Fig. 4-1:

Single-phase power connections for the MR-J3-T amplifier

1-phase

200–230V AC

Servo motor

Motor

Encoder

Encoder cable

Alarm

EMG. OFF OFF

ON

EMG. OFF

Servo ON

Servo amplifier

24V DC

24V DC ± 10 %
800 mA

24V DC

24V DC ±10%
150mA