4.4

Configuration for Positioning

If you install the MR-J3-D01 I/O expansion you can use point table positioning, which allows you
to select positions from a list of up to 256 table entries with a combination of eight digital inputs.
Table 4-3 shows how binary input signals are encoded to address the point table entries.

In the factory default configuration the incremental system is activated, which means that the
absolute position detection system is turned off (PA03 “absolute position detection system”).In
this mode the current position is not stored when the power is turned off and you must thus per-
form a home position return every time the amplifier is powered on. The default configuration
also uses absolute target positions (PA01 “positioning control mode”).

To activate this parameter you must switch the amplifier power off and on again.

Positioning with Digital Inputs

Configuration for Positioning

MR-J3-T

4 - 23

Digital Input Signals

Selected Point

Table Entry

DI7

DI6

DI5

DI4

DI3

DI2

DI1

DI0

0

0

0

0

0

0

0

1

1

0

0

0

0

0

0

1

0

2

0

0

0

0

0

0

1

1

3

0

0

0

0

0

1

0

0

4

·
·
·

·
·
·

·
·
·

·
·
·

·
·
·

·
·
·

·
·
·

·
·
·

·
·
·

1

1

1

1

1

1

1

0

254

1

1

1

1

1

1

1

1

255

Table 4-3: Selection of point table entries with digital input signals

No.

Code

Function

Description

PA01

*STY

Positioning control
mode

0: Absolute target position values
1: Incremental target position values

PA03

*ABS

Absolute position
detection system

0: Incremental system (absolute detection off)
1: Absolute position detection system on

PA05

*FTY

Feed length multi-
plication factor

Needed here to scale the home position value to the physical coor-
dinate system when a home position offset (shift) has been set.

Table 4-4: Parameter reference

Parameter
value

Multiplication
factor STM

Range of the target
position values

0

1

999.999 .. +999.999

1

10

9999.99 .. +9999.99

2

100

99999.9 .. +99999.9

3

1000

999999 .. +999999

Advertising