NOTES

You can find a brief descriptions of the signal functions in Appendix A.1. Please refer to the
instruction manual for a complete reference.

All digital signals described in this manual use source logic.

For safety reasons the EMG signal must be connected to pin 1 of connector CN6 if the
servo amplifier is not operated during the first functional test. The EMG signal is perma-
nently assigned to pin 1 and the amplifier is deactivated when there is no EMG signal if it is
configured accordingly (see chapter 3.2).

Positioning with Digital Inputs

Additional Connections

MR-J3-T

4 - 13

Fig. 4-3:

Connection of the control terminals with PNP logic (source logic)

24V DC ±10%
150mA

24V DC

EMG. OFF

Proximity dog

Forward stroke end

Reverse stroke end

max. 10m

max. 10m

24V DC ±10%
800mA

24V DC

Point

table

selection

SERVO ON

RESET

Automatic/Manuall

Forward rotation start

Reverse rotation start

A 24V 1000mA power supply can be
used for all control terminals.

max. 10m

In position

Alarm code

MR-J3USBCBL3M

(Option)

max.10 m