2 functional test settings 3-7, Settings 3 - 7, Selecting 3 - 7 – MITSUBISHI ELECTRIC MR-J3-T User Manual
Page 15: ᕡᕢ ᕣ, 2 functional test settings
Advertising
3.2
Functional Test Settings
The following input signals are required to activate the servo amplifier’s motor output:
b
EMG -> Force stop (safety signal)
b
SON -> Servo ON
b
LSP -> Forward rotation stroke end (limit switch)
b
LSN -> Reverse rotation stroke end (limit switch)
You can configure the servo amplifier to activate these signals automatically when the power is
switched on:
Procedure:
ቢ
Connect the PC / notebook to the servo amplifier’s USB port (CN5) with the
MR-J3USBCBL3M cable.
ባ
Start MR Configurator on the computer and make the following settings:
– Select the MR-J3-T series servo amplifier:
First Functional Test
Functional Test Settings
MR-J3-T
3 - 7
Fig. 3-3:
Selecting the servo amplifier
ᕡ
ᕢ
ᕣ
Advertising