A.2 standard parameters - quick reference a-40, Quick reference a - 40, A.2 standard parameters quick reference – MITSUBISHI ELECTRIC MR-J3-T User Manual

Page 47: Table a-2: standard parameters quick reference

Advertising
background image

A.2

Standard Parameters

Quick Reference

To activate this parameter you must switch the amplifier power off and on again.

Standard Parameters

Quick Reference

Appendix

A - 40

MITSUBISHI ELECTRIC

No.

Code

Function

Description

PA01

*STY

Positioning control
mode

0: Absolute value command system for target positions
1: Incremental value command system for target positions

PA03

*ABS

Absolute position
detection system

0: Incremental system (absolute position detection off)
1: Absolute position detection system on

PA05

*FTY

Feed length multipli-
cation factor

Needed here to scale the home position value to the physical co-
ordinate system when a home position offset (shift) has been set.

PA14

*POL

Servo motor rotation
direction

Motor rotation direction (looking at shaft end facing motor):
0: Anticlockwise when ST1 signal is active
1: Clockwise when ST1 signal is active

PC02

*ZTY

Home position re-
turn mode

Selects mode to be used for home position return:
0: Proximity dog mode

PC03

*ZDIR

Home position re-
turn direction

0: Incrementing counting of encoder pulses
1: Decrementing counting of encoder pulses

PC04

ZRF

Home position re-
turn speed

Sets home position return speed until first detection of the
Z-phase in [rpm].

PC05

CRF

Creep speed

Speed for precise movement to home position in [rpm]

PC06

ZST

Home position
offset (shift)

Distance between the encoder home position (Z-phase) and the
physical home position in [µm]. Does not change the zero point of
the physical coordinate system.

PC07

*ZPS

Home position re-
turn position value

The home position return stops when the Z-phase position is
reached.You can enter a non-zero coordinate for this position [in
10

STM

µm] with this parameter.

PD01

*DIA1

Automatic activation
of input signals

This parameter configures the amplifier to automatically set the
digital signals internally to a logical "1" when the power is
switched on.

PD01

*DIAB

Polarity of the input
signal

Logical value for detection of the proximity dog signal (DOG):
0: Active DOG on logical "0"
1: Active DOG on logical "1"

Table A-2: Standard parameters

quick reference

Parameter
value

Multiplication
factor STM

Range of the target
position values

0

1

999.999 ... +999.999

1

10

9999.99 ... +9999.99

2

100

99999.9 ... +99999.9