Ss38 direct vent gas stove – Monessen Hearth SS38 User Manual

Page 15

Advertising
background image

15

46D0232

SS38 Direct Vent Gas Stove

HORIZONTAL TERMINATION
CONFIGURATIONS

Figures 15 through 17 show different configurations for
venting with horizontal termination. Each figure includes
a chart with vertical minimum/maximum and horizontal
maximum dimensions which must be met. All horizontal
terminations require a 1/4" rise per 12" of horizontal run.
NOTE: Add 1/4" rise per 12" horizontal length of pipe.

VENTING INSTALLATION

Table 1 - Horizontal Venting

Vertical (V) Minimum

Horizontal (H) Maximum

5'

30"

6'

8'

8'

20'

NOTE: This configuration is for use with corner
installation also.

Figure 15 -
Horizontal Termination Configuration for Rigid
Venting Using One 90° Elbow

HOT

H

V

ST1105
horz term 1 elbow

ST1105

Table 2 - Horizontal Venting with Two (2) 90° Elbows
Vertical (V) Horizontal (H)

Horizontal (H) +

Minimum

Horizontal (H

1

) Max.

7'

4' Max.

8'

8'

6' Max.

12'

9'

8' Min.

20'

20'

8' Max.

20'

NOTE: Add 1/4" rise per 12" horizontal length of pipe.

H

V

H

1

ST1106
horiz term 2 elbows

Figure 16 -
Horizontal Termination Configuration for Rigid
Venting Using Two 90° Elbows

ST1106