Ss38 direct vent gas stove, Product features product specifications, Installing above 2000 feet – Monessen Hearth SS38 User Manual

Page 5: Gas pressures, Gas specifications & orifice size

Advertising
background image

5

46D0232

SS38 Direct Vent Gas Stove

PRODUCT FEATURES

PRODUCT SPECIFICATIONS

This appliance has been certified for use with either

natural or propane gas. See appropriate data plates.

This appliance is not for use with solid fuels.

The appliance is approved for bedroom or bedsitting

room installations.

The appliance must be installed in accordance with local

codes if any. If none exist use the current installation
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.

This appliance is mobile home approved.

The appliance must be properly connected to a venting

system.

The appliance is not approved for closet or recessed

installations.

For alcove installation see “Clearances,” Page 8.

ON/OFF

PIL

OT

HEA

T

OFF

FAN

ST1099
SS38 controls

Off/Pilot/On
Knob

Optional Remote
Receiver

Door

Figure 1 -
SS38 Stove Controls

Hi/Lo Knob

On/Off/RS
Switch

Blower

ST1099

INSTALLING ABOVE 2000 FEET

In the USA, the appliance must be derated 4% for every

1,000 ft. above 2,000 ft elevations.

In Canada, these applications are certified for altitudes
of 0 - 2,000 ft, and must be derated by 10% for installa-
tions between 2,000 and 4,500 ft. (derate an additional
4% for every 1,000 ft. above 4,500 ft. elevations.)

GAS PRESSURES

Natural

Propane (LP)

Inlet Minimum

4.5” w.c.

11.0” w.c.

Inlet Maximum

10.5” w.c.

13.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

GAS SPECIFICATIONS & ORIFICE SIZE

Max.Input Min. Input

Orifice

Model

Fuel

BTU/h

BTU/h

Size

SS38NV

Nat.

38,000

27,000

#32

SS38PV

LP

35,000

25,000

#50

The Stratford SS38 is equipped with a variable output
gas control.