MultiModemBL User Guide

S-REGISTER

UNIT

RANGE

DEFAULT

DESCRIPTION

S24

50 mSec

0-255

20

Sets DSR/CTS/CD dropout time. Default
(20) equals one second.

S25

100 mSec 0-255

0

Sets DTR dropout time. 0 default equals 50
mSec.

S26

1

0-255

0

Specifies number of failed password
attempts allowed.

S29

1

1-255

20

Specifies the amount of idle time can elapse
between AT commands after the SETUP
password has been entered

S30

min 0-255

0

Inactivity timer used to disconnect modem.

S32

100mSec 0-255

20

Sets time that modem waits for a

<RETURN> to be entered during escape
sequence execution.

S34

ASCII

0-60

10

Buffer size for number of characters in AT
command string after on-line escape
sequence, before buffer is cleared and
escape sequence aborted.

S36

1 second 0-255

0

S36 sets the time between DTR inactive and
the modem going off-hook (busy-out).

S37

1 second 0-255

5

S37 sets the time allowed DTR active and
the modem responding on-hook (not busy).

* S48

N/A

33, 31,

0

S48 sets maximum speed modem connects

28, 26, 24,

within scope of Enhanced V34

21, 19, 16,

mode (e.g., S48 = 21 means

14, 12, 96

maximum connect speed is

and 48

21.6K)

. This register is useful when line

conditions will not support higher V34
speeds. The default value is 0, which
indicates a connection attempt of 28.8K.

lower speeds are still enabled.

* 2834 Series only

Advertising