Chapter 5 - Command Mode

CONTROL RS232C

&C

Carrier Detect Control

INTERFACE

&D

Data Terminal Ready Control

&R

Clear To Send Control

&S

Data Set Ready Control

&RF

CTS/RTS Control

&SF

DSR/CD Control

CONFIGURE

&E0

Normal Mode

ERROR

&E1

Auto-Reliable Mode

CORRECTION

&E2

Reliable Mode

#L0

Negotiate V.42 Mode During Handshake

#L1

MNP On/LAPM Off

#L2

LAPM On/MNP Off

#L3

Direct LAPM/Phase Out Handshake

$A

Auto-Reliable Buffering

$F

Enable/Disable Auto-Reliable Fallback Character

$R

Retransmit Count

$E

Error Correction at 300 bps

CONFIGURE

&E3

Flow Control Disabled

FLOW CONTROL

&E4

Hardware Flow Control

&E5

Xon/Xoff Modem-Initiated

&E6

Xon/Xoff Modem Responds/No Pass-Through

&E7

Xon/Xoff Modem Responds/Pass-Through Allowed

#X

Send Single/Multiple Xoff Characters

&E8

Enq/Ack Off

&E9

Enq/Ack On

&E10

Normal Mode Modem Flow Control Off

&E11

Normal Mode Modem Flow Control On

&E12

Computer-Initiated/Off

&E13

Computer-Initiated/On

&BS

Maximum Block Size

$EB

10/11 bit Asynchronous Format

#P

Parity Selection

CONFIGURE DATA

&E14

Data Compression Disabled

COMPRESSION

&E15

Data Compression Enabled

CONFIGURE SPEED

$BA0

Speed Conversion On

CONVERSION

$BA1

Speed Conversion Off

$MB

Set modem speed (e.g.,$MB14400)

$SB

Set serial port speed (e.g.,$SB57600)

EXECUTE

$H

Help

IMMEDIATE

I

Product Code Inquiry

ACTION

I 9

Windows 95 Autodetect Inquiry (2834 Series only)

COMMANDS

L5

List Current Operating Parameters

L6

List S-Register Values

L7

List additional Configuration Parameters

L8

List On-Line Diagnostics

H

Off Hook

+++AT<CR>

Escape Sequence: Entering Command Mode while On-Line

%E

Escape Sequence Options...Entering Command Mode while On-Line

A

Force Answer Mode

O

Exit Command Mode/Go Back On-Line