Operation examples (continued) – MITSUBISHI ELECTRIC DX-NT400E User Manual

Page 60

Advertising
background image

60

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

Operation examples (continued)

1

<MOTION DETECTION SETTINGS>
>>SELECTION CAMERA NUMBER
DETECTION MASK SETTING
SENSITIVITY HIGH••<<<LOW
MOTION THRESHOLD 5
TEST MODE
MD LOCK OUT TIME OFF

4) <TIMER PROGRAM SETTINGS> screen setting (
see pages 44 to 46)

• SELECTED PATTERN: “P3”
• ALARM REC DURATION: “5M”

<TIMER PROGRAM SETTINGS>
>>SELECTED PATTERN P3-SET
HOLIDAY SETTING
REC MODE A
REC MODE B
REC MODE C
REC MODE D
ALARM REC DURATION 5M

5) <ALARM SETTING C> screen setting (

see page

46)

• All the cameras (“

1

” to “

4

”):

• TRIGGER: “MD/EXT”

• EMR: Set all the cameras (“

1

” to “

4

”).

<ALARM SETTING C>
ALARM RECORD CAMERA TRIGGER
>>1 --- MD/EXT
2 - -- MD/EXT
3 -- - MD/EXT
4 --- MD/EXT
EMR

ALARM TYPE ALARM CH

CLEAR:BACK

4

1

2

3

4

1 2 3

6) <RECORD SETTING C> screen setting (

see page

46)

• All the cameras (“

1

” to “

4

”):

• PPS, GRADE, A-PPS, A-GRADE: Set the desired
interval and picture quality for each camera.
• ALARM TYPE: “ALARM CH”
• PRE ALARM REC: Set the desired pre-alarm
recording time.

4

1

2
3

<RECORD SETTING C>
NO PPS GRADE A-PPS A-GRADE
>> 3.125P STD 3.125P HIGH
3.125P STD 3.125P HIGH
3.125P STD 3.125P HIGH
3.125P STD 3.125P HIGH

ALARM TYPE ALARM CH
PRE ALARM REC MEDIUM

CLEAR:BACK
<ESTD REC> D H M

7) <ALARM SETTING D> screen setting (

see page

46)

• Camera numbers “

1

” and “

3

” only:

• TRIGGER: “MD/EXT”

<ALARM SETTING D>
ALARM RECORD CAMERA TRIGGER
>>1 --- MD/EXT
2 - -- EXT
3 -- - MD/EXT
4 --- EXT
EMR

ALARM TYPE ALARM CH

CLEAR:BACK

4

1

2

3

4

1 2 3

8) <RECORD SETTING D> screen setting (

see page

46)

• Camera numbers “

1

” and “

3

” only:

• PPS, GRADE, A-PPS, A-GRADE: Set the desired
interval and picture quality for each camera.

• Other camera:

• PPS, GRADE: “- - - - - -”
• ALARM TYPE: “ALARM CH”

• PRE ALARM REC: Set the desired pre-alarm recording
time.

4

1

2
3

<RECORD SETTING D>
NO PPS GRADE A-PPS A-GRADE
>> 6.25P SUPER ------ STD
------ STD ------ STD
6.25P SUPER ------ STD
------ STD ------ STD

ALARM TYPE ALARM CH
PRE ALARM REC MEDIUM

CLEAR:BACK
<ESTD REC> D H M

9) <TIMER PROGRAM> screen setting (

see page 44)

• PROGRAM NO.1 : “SPL,” “08:00,” “15:00,” “C,” “ON.”
• PROGRAM NO.2 : “SPL,” “15:00,” “08:00,” “D,” “ON.”
• PROGRAM NO.3 : “SAT,” “08:00,” “08:00,” “D,” “ON.”
• PROGRAM NO.4 : “SUN,” “08:00,” “08:00,” “D,” “ON.”
• SPL: “MON - FRI”

<TIMER PROGRAM> P3
DW START END MODE MD
>>1 SPL 08:00 15:00 C ON
2 SPL 15:00•08:00 D ON
3 SAT 08:00•08:00 D ON
4 SUN 08:00•08:00 D ON
5 --- --:-- --:-- ---- ---
6 --- --:-- --:-- ---- ---
7 --- --:-- --:-- ---- ---
8 --- --:-- --:-- ---- ---

SPL MON-FRI

When completed with all the settings above and after
clearing the menu screen, press both the TIMER ON/
OFF buttons. The unit switches to the timer
programming mode.

Advertising