Fp2501 manual pilot flame, Eyf series unvented gas log set flame appearance, Fp2273 pilot bad flame – Monessen Hearth EYF18 User Manual

Page 18: Check the pilot flame, Millivolt control, Manual & hi/lo control

Advertising
background image

65D1009

18

EYF Series Unvented Gas Log Set

FLAME APPEARANCE

FP2501
manual pilot flame

FP2273
pilot bad flame

FP2272
pilot correct flame

Flames from the pilot, front and rear burner should be visually checked as soon as the
heater is installed.
In addition, periodically check the flames visually during operation.

ChECk ThE PILOT fLAME

The pilot flame must always be present when the heater is in operation. It should just
touch the top of the thermocouple tip for natural. Refer to Figures 29 & 30 for correct pilot
flame.
If the pilot flame does not touch the thermocouple, then the main burner cannot function
reliably. Refer to Figures 29 & 30 for incorrect shape of pilot flame.

Figure 29 -
Millivolt Control Pilot Flame Appearance

Thermocouple
for Natural Gas

Thermocouple
for LP

FP7

Thermocouple
for Natural Gas

Thermocouple
for LP

FP73

MILLIVOLT CONTROL

Correct Pilot Flame Appearance

Incorrect Pilot Flame Appearance

MANUAL & HI/LO CONTROL

Thermocouple
for Natural Gas

Thermocouple
for LP

Thermocouple
for Natural Gas

Thermocouple
for LP

FP50

Correct Pilot Flame Appearance

Incorrect Pilot Flame Appearance

Figure 30 -
Manual & Hi/Lo Control Pilot Flame Appearance

Advertising
This manual is related to the following products: