Monessen Hearth EYF18 User Manual

Page 5

Advertising
background image

5

65D1009

EYF Series Unvented Gas Log Set

W

ARNING

Gloves are recommended when
handling ceramic fiber logs to prevent
skin irritation from loose fibers.

Logs are fragile - handle with care.

MAkE SURE YOU HAVE RECEIVED ALL
PARTS:

Check your packing list to verify that all listed parts have
been received. You should have the following:

Unvented gas log burner assembly

Plastic bag containing crushed volcanic rock

Installation/operating instructions

Two () anchoring screws

Ceramic Fiber or Refractory Cement Logs

Grate

The millivolt controlled version of this heater is the only
style designed to be operated with optional devices for
ON/OFF functions. The following options may be used
with the millivolt controlled heater. These options are not
packaged with the log set.

Hand held Remote with receiver

Wall thermostat with 15' wire

Wall switch with 15' wire

Hand held Thermostat Remote with receiver

Carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately inform the
dealer from whom you purchased the appliance. Do not
attempt to install any part of the appliance unless you
have all parts in good condition.

WHAT YOU WILL NEED FOR INSTALLA-
TION:

You must have the following items available before pro-
ceeding with installation:

External regulator (for propane/LPG and 1/ lb.
natural gas systems only)

Piping which complies with local codes

Screwdriver

Drill with 5/3 bit

Manual shutoff valve

Pipe sealant approved for use with propane/LPG
(Resistant to sulfur compounds)

Pipe wrench or appropriate size crescent wrench
set

Tee joint.

Sediment trap

GAS SPECIFICATIONS

Gas Rate

Max.Input Min. Input

Model

Fuel Control

BTU/h BTU/h

EYF18NM

Nat. Manual

30,000 18,000

EYF18PM

LP Manual

30,000 ,500

EYF18NV

Nat. Millivolt

30,000 0,000

EYF18PV

LP Millivolt

30,000 4,500

EYF4NM

Nat. Manual

36,000 19,000

EYF4PM

LP Manual

36,000 5,000

EYF4NV

Nat. Millivolt

36,000 4,000

EYF4PV

LP Millivolt

36,000 9,000

*NOTE: An external regulator is required to reduce supply pres-
sure to a maximum of 13” w.c.

GAS PRESSURES

Control

Fuel

Manual

Millivolt

Regulator Pressure

Nat.

4.0” w.c.

3.5” w.c.

Pilot Regulator

Nat.

n/a

3.5” w.c.

Max. Inlet Pressure

Nat.

10.5” w.c.

10.5” w.c.

Min. Inlet Pressure

Nat.

5.0” w.c.

5” w.c.

Regulator Pressure

LP

10.0” w.c.

10.0” w.c.

Max. Inlet Pressure

LP

13.0” w.c.

13.0” w.c.

Min. Inlet Pressure

LP

11.0” w.c.

11.0” w.c.

IGNITION CONTROLS

Piezo ignitor allows ignition of the pilot without the use of
matches or batteries.
Manual control has three (3) positions:
OFF - All gas to the gas logs is shut off at the valve.
IGN - Valve position to light/maintain a standing pilot.
HI/LOW - Variable position corresponding to desired

flame height (heat input)

Millivolt control has four (4) positions:
OFF - All gas to the gas logs is shut off at the valve.
IGN - Valve position to light/maintain a standing pilot.
ON - Valve position to turn ON/OFF log set with remote

switch/thermostat.

HI/LOW - Variable position to control flame height (heat

output).

PILOT
The gas log heater is fitted with a specially designed safety
pilot light (ODS assembly) which senses the amount of
oxygen available in the room and shuts the gas log heater
off if the oxygen level begins to drop below a satisfactory
level. The pilot can only be relit when adequate fresh air
is available.
THERMAL GENERATOR
The millivolt gas log pilot is fitted with a millivolt generator
to provide power for remote activation.

GETTING STARTED - FEATURES and SPECIFICATIONS

Advertising
This manual is related to the following products: