Fp2533 mantel clear no hood – Monessen Hearth EYF18 User Manual

Page 8

Advertising
background image

65D1009

8

EYF Series Unvented Gas Log Set

INSTALLATION

The dimensions shown in Figures 4 through 10 and defined in the fireplace
manufacturer's instructions are minimum clearances to maintain when
installing this heater. Left and right clearances are determined when
facing the front of the heater.
When heater is installed into a ventless firebox, minimum clearances,
as specified by the ventless firebox manufacturer, must be met.
Follow these instructions carefully to ensure safe installation. Failure
to follow instructions exactly can create a fire hazard.

Sidewall and ceiling clearances: The sides of the fire-
place opening must be at least 16" from any combustible
wall. The ceiling must be at least 42" from the top of the
fireplace opening.

16"

42"

FP1996
wall ceiling clearances

Figure 4 -
Sidewall and Ceiling Clearances

FP1996

Heat resistant material (minimum requirements) with
no wooden mantel or other combustible projection:

To install the gas logs into a fireplace with no wooden
mantel, shelf or other combustible projection above the
fireplace opening, measure the heat resistant material
height, per Figure 5, then see TABLE A.
Heat resistant materials such as slate and marble must be
at least

1

/2" thick. Sheet metal should not be installed

onto combustible material.
IMPORTANT:
If you cannot meet these minimum clear-
ances you must operate the heater with chimney flue
damper open. See Installing Vented Applications found
on page 16.

W

ARNING

FP2533
mantel clear no hood

Heat
Resistant
Material

Measure This
Distance

Heater in Fireplace
or Firebox

FP533

Figure 5 -
Mantel Clearance without Hood

Heat Resistant Material EYF24/18 Requirements

Measurement

for Safe Installation

0" or more

Hood not required

8" to less than 0"

Extend heat resistant material

to 0" or install hood. Figure 6

Less than 8"

Extend heat resistant material

to at least 8" and install hood.

Figure 6. OR, extend heat

resistant material to a height

of at least 0".

Table A -
Heat Resistant Material Requirements with No
Mantel or Combustible Projection

CLEARANCE and HEIGHT REQUIREMENTS