1

65D1009

EYF Series Unvented Gas Log Set

OPERATING INSTRUCTIONS

MANUAL CONTROL LIGhTING INSTRUCTIONS

1. STOP! Read the safety information.
. Make sure the manual shutoff valve is fully open.
3. This heater is equipped with an ignition device (piezo) which automatically

lights the pilot.

4. Refer to Page 22, Figure 37 for the location of the piezo ignitor and control

knob. Push in gas control knob slightly and turn control knob clockwise

to the OFF position.

NOTE: Knob cannot be turned to OFF unless knob is pushed in slightly. Do
not force.

5. Wait 5 minutes to clear out any gas. Then smell for gas, including near the

floor. If you smell gas STOP! Follow the instructions under “What to Do if You
Smell Gas”, Page 20. If you do not smell gas, go to the next step.

6. From OFF position, push in gas control knob slightly and turn counterclock-

wise

to the IGN position. Figure 33. Push in and hold control knob for 5

seconds.

NOTE: If you are running the heater for the first time, it will be necessary to
press in the control knob for 30 seconds to allow air to bleed out of the gas
piping.

7. With the control knob pushed in, push and release the piezo ignitor button to

light the ODS pilot. The pilot is located on the left side of the heater, behind
the middle log and in front of the back log. If piezo ignitor does not light the
pilot, refer to “Match Lighting Instructions”, Page 23.

8. Hold the control knob in for an additional 10 seconds to prevent the ODS pilot

from shutting off the gas while the thermocouple is warming up.

9. Release the control knob.

If the knob does not pop out when released, stop and immediately call your

service technician or gas supplier.

If the ODS pilot will not stay lit after several tries, push and turn the gas

control knob clockwise

to OFF and wait 15 seconds. Repeat steps 6

through 9.

10. Push in control knob and turn counterclockwise

to the HIGH setting. At

this location the control knob will pop out when positioned correctly. The knob
can now be positioned at any position between HIGH and LOW. Figures 34
and 35

Rotate

Push

Figure 33 -
IGN Position

Figure 34 -
HIGH Position

Rotate

Push

Figure 35 -
LOW Position

Rotate

W

ARNING

Wait 30 seconds before readjusting the
heater when the control knob has been
turned down to a lower setting.

1. Turn control knob clockwise

to OFF position to completely shut off the heater.

. If applicable: Turn off all electric power to the heater.

TO TURN Off GAS TO hEATER