Eyf series unvented gas log set flame appearance, Operating instructions, Lg717 eyf flame height – Monessen Hearth EYF18 User Manual

Page 19

Advertising
background image

19

65D1009

EYF Series Unvented Gas Log Set

FLAME APPEARANCE

In normal operation at full rate after 15 minutes, the following flame appearances should
be observed:
The left and right flames should be yellow and extend 1" to " above the log top surfaces. The
yellow flames should not contact the logs.

OPERATING INSTRUCTIONS

Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into the
fireplace. Do not place a blower inside the burn area of the firebox. Ceiling fans may create
drafts that alter flame patterns. Sooting and improper burning will result.
During manufacturing, fabricating and shipping, various components of this appliance are
treated with certain oils, films or bonding agents. These chemicals are not harmful, but may
produce annoying smoke and smells as they are burned off during the initial operation of the
appliance, possibly causing headaches or eye or lung irritation. This is a normal and temporary
occurrence.
The initial break-in operation should last two to three hours with the burner at the highest setting.
Provide maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors
remaining after this initial break-in will be slight and will disappear with continued use.
This appliance must not be used with glass doors in the closed position. This can lead to pilot
outages and severe sooting outside the fireplace.

LO

HI

OFF

ON

I

G

N

LG717
EYF flame height

Figure 31 -
Correct Burner Flame Appearance

LG717

Advertising