Step 1:

Rough Opening and Framing Requirements (cont.)

Figure 2: Preparing openings for concrete block openings.

1

Rough opening gap must be no more than 1/4, for products certified for use in IZ4 regions.

CAUTION! If the previous conditions are

not met, the installer must take corrective

actions to alter the opening(s) before

proceeding. It is also essential that the sheathing

behind the wall be a solid surface to ensure that

the unit can be secured firmly to the wall.

NOTE: On standard wood frame construction with

brick veneer, make sure there is at least 1/2,

(13)

between bottom of window sill (or eventual

placement of the window) and the top row of brick

to avoid “brick bind”.

ATTENTION: B

e aware that use of rigid sill pans and

other barriers will decrease the rough opening height
clearance. Adjust opening dimensions accordingly.

Rough Opening

Masonry Opening

1/2,

1/2,

1/4,

1/4,

5. Rough openings

1

(RO) should be 1,

(25)

wider than

the outside measurement of the frame and 1/2,

(13)

higher. Masonry openings (MO) should be 1/2,

(13)

wider than the outside measurement of the frame or

casing and 1/4

, (6)

higher than the outside measure-

ment of the frame or casing. When framing rough

opening, care should be taken to ensure the sill plate

is level and the opening is square, straight and plumb.

See figure 2.

5

Window Installation

StormPlus and Structural Installations

19970019

2013−03−01

Advertising