Fastening Methods and Jamb/Sill Screw Chart

Although structural installations may involve fastening with wood brick mould casing or nailing fin, there are two ways

to fasten your jambs to the opening for structural purposes:

1. #8 Wood screws (or 3/16, concrete anchors), 6, (152) from all corners and

15, (381) on center around the perimeter.

or

2. Structural brackets, 6, (152) from all corners and 15, (381) on center around the perimeter.

Refer to the “Jamb/Sill Screw Chart” for proper fastening requirements for your particular product. Illustrations

show a concrete block opening but apply to typical wood frame construction as well.
NOTE: All mulled units require fastening with two screws or brackets on each side of the mull joint no more than

6, (152) from mull joint.
NOTE: Single UDH products do not require fastening at the sill. Multiple wide UDH assemblies require anchoring

at the sill mullion. UDHM IZ3 units must be installed with jamb screws, fastening at the sill is not required.

Jamb/Sill Screw Chart

Structural Brackets

1. Wrap brackets around the framing/buck/opening,

fasten with two #8 x 1 5/8, screws. Angle the screws

approximately 15 degrees away from the window.

Always shim above or behind installation brackets.

Figure 7

1/4,

5/32, holes

Shim

Screws

Jamb/Sill Screws

1. Space fasteners along jambs and head jambs no

more than 6, (152) from each corner and 15, (381)

on center. Follow same spacing for sills when appli-

cable.

NOTE: Structural brackets are allowable replacements

for screws if fastening at the sill is necessary.

2. After removing covers or liners, fasten units to the

framing with #8 wood screws or 3/16, concrete an-

chors

1

. Adjust length of fastener so that it penetrates

no less than 1 1/4,

(32)

into framing/opening. When

fastening through the sill, always pre−drill and fill

hole with sealant before driving the screw. Always

place a shim behind or above the screw location on

jambs and head jambs.

NOTE: When using masonry anchors, be sure to follow

manufacturer’s guidelines for proper installation. Some

types require pre−drilling.

1

Use concrete anchors when wood buck material is less than 2, nominal thickness.

8

Window Installation

StormPlus and Structural Installations

19970019

2013−03−01

Product

Jamb Screw

Length

Sill Screw

Length

Clad Ultimate

Casement Family

and Direct Glaze

3, (76)

2 1/2, (64)

Wood Ultimate

Casement Family

and Direct Glaze

3, (76)

3 1/2, (89)

Ultimate Double

Hung Family

2 1/2, (64)

N/A

Ultimate Double

Hung Magnum

Family*

Supplied

with unit

N/A

* Use predrilled holes in frame members.