Safe Installation Dos and Don’ts

DO adhere to all National and Local Plumbing and
Electrical Safety Codes.

DO turn OFF incoming electrical service switches
when servicing, installing, or repairing equipment.

DO check that all flare fittings are tight. This check
must be performed with a wrench to ensure a quality
seal.

DO inspect pressure on regulators before starting up
equipment.

DO protect eyes when working around refrigerants.

DO use caution when handling metal surface edges
of all equipment.

DO handle CO

2

cylinders and gauges with care.

Secure cylinders properly against abrasion.

DO store CO

2

cylinder(s) in well ventilated areas.

DO NOT exhaust CO

2

gas (example: syrup pump)

into an enclosed area, including all types of walk-in
coolers, cellars, and closets.

DO NOT throw or drop a CO

2

cylinder. Secure the

cylinder(s) in an upright position with a chain.

DO NOT connect the CO

2

cylinder(s) directly to the

product container. Doing so will result in an explosion
causing possible death or injury. It is best to connect
the CO

2

cylinder(s) to a regulator(s).

DO NOT store CO

2

cylinders in temperature above

125°F (51.7°C) near furnaces, radiator or sources of
heat.

DO NOT release CO

2

gas from old cylinder.

DO NOT touch refrigeration lines inside units; some
may exceed temperatures of 200°F (93.3°C).

NOTICE: All utility connections and fixtures must be
sized, installed, and maintained in accordance with
Federal, State, and Local codes.

!

Warning

Read the following warnings before beginning an
installation. Failure to do so may result in possible
death or serious injury.