Sanitizing

BEVERAGE SYSTEM CLEANING

Sanitize the beverage system at initial start-up as well as
regularly scheduled cleaning. The drain pan must be in
place under soda valves, to carry away detergent and
sanitizing agents that will be flushed through valves.

BAG-IN-BOX SYSTEM SANITATION

The procedure below is for the sanitation of one
syrup circuit at a time. Repeat to sanitize additional
circuits.

You will need the following items to clean and sanitize
the Bag-in-Box (BIB) beverage system:

Three (3) clean buckets

Plastic brush or soft cloth

Mild detergent

Unscented bleach (5% Na CL O) or
Commercial sanitizer

Bag-In-Box bag connector

1. Prepare the following in the buckets:

Bucket 1 — warm to hot tap water for rinsing.

Bucket 2 — mild detergent and warm to hot
water.

Bucket 3 — mix a solution of unscented bleach
(5% Na CL O) or commercial sanitizer and warm to
hot water. Mixture should supply 100 PPM
available chlorine (1/4 oz. bleach to 1 gallon water).

2. Disconnect the “syrup-line side” of the BIB

connector.

3. Rinse connector with warm tap water.

4. Connect syrup connector to BIB connector and

immerse both into Bucket 1. A “bag-side” connector
can be created by cutting the connector from an
empty disposable syrup bag.

!

Warning

Flush sanitizing solution from syrup system.

Residual sanitizing solution left in system could
create a health hazard.

!

Warning

When using cleaning fluids or chemicals, rubber
gloves and eye protection must be worn.