Back-flow preventer maintenance, Shipping, storage and relocation – Manitowoc Ice MULTIPLEX 11M User Manual

Page 37

Advertising
background image

Section 4

Maintenance

Part Number 020001552 5/11

4-3

Back-flow Preventer Maintenance

The integral carbonator in this unit is equipped with a
back-flow preventer designed to protect the potable
water supply from CO

2

contamination.

1. Shut OFF power to unit.

2. Shut OFF potable water supply to unit. Do not shut

OFF CO

2

supply.

3. Remove top cover panel of unit and disconnect inlet

fitting from back-flow preventer.

NOTE: The carbonator tank is still pressurized.

4. Observe inlet of backflow preventer #1 check for any

discharge. If there is no discharge, #1 check is OK.
Proceed to step 5. If there is discharge, proceed to
step 6.

5. Disconnect and carefully remove #1 check

assembly. Avoid losing any internal parts.

6. Observe inlet of #2 check for any discharge. If there

is no discharge, #2 check is OK. Proceed to step 7.
If there is discharge, proceed to step 5.

7. Shut OFF CO

2

supply and relieve pressure from

carbonator tank.

8. Remove back-flow preventer and install new

backflow preventer. Turn ON CO

2

supply and check

for leaks.

9. Check water supply strainer upstream of backflow

preventer. Clean out and/or replace as required.

10. Reconnect water lines and turn water supply ON.

11. Turn ON power to unit.

Shipping, Storage and Relocation

Important

The back-flow preventer must be checked at least
once every year to confirm that it is functioning
properly.

! Caution

Before shipping, storing, or relocating this unit, syrup
systems must be sanitized. After sanitizing, all
liquids (sanitizing solution and water) must be
purged from the unit. A freezing environment causes
residual sanitizing solution or water remaining inside
the unit to freeze, resulting in damage to internal
components.