Section 2

Installation

Part Number 020001552 5/11

2-13

2. Connect the circulating water by connecting one line to

the circulating pump outlet line (3/8” barb) and clamp in
place. Connect the other line to the bulkhead return
fitting located by the agitator motor (3/8” barb) and
clamp in place.

3. Connect the conduit lines. Two (2) carbonated water

lines and two (2) product output lines (#1 regular
rootbeer & #2 diet rootbeer)

CONNECTING SUPPLY LINES

Connect water supply inside unit.

Pre-installation of towers is required and the appropriate
syrup supply must be connected to the corresponding tower.

Proceed with the Following Tests

Ensure that overflow tube is firmly seated, not leaking.

Check conduit for proper support and insulation.

Cycle carbonator “A” momentarily.

Cycle circulating Motor “A” momentarily.

Cycle compressor momentarily.

Ensure that agitator motor is running.

Ensure that ice bank control probe is securely attached
to evaporator coil.

Connect CO

2

supply inside unit.

Connecting conduit at the refrigeration unit

1. Connect the product lines either from the bag-in-box or

tank (#1 regular rootbeer & #2 diet rootbeer). See the
plumbing diagrams for the tower setup that pertains to
your installation.

2. Insert the Multipar conduit into the outlet opening on the

left hand side of unit. Conduit insulation must extend
inside of opening in unit for proper operation of
equipment.

NOTE: Multipar conduit is color coded for easy
identification of lines. When making connections always
attach lines requiring the longest connection from the
insulation first. The remaining lines can be trimmed as
required to make the routing neat and secure.

3. Locate the two blue carbonated water lines of the Multipar

conduit. Attach one of the blue lines to the tee fitting
located on top of the carbonator tank. Attach the other
blue line to John Guest elbow fitting on the stainless coil
labeled “8”.

4. Locate the black plain water line of the Multipar conduit.

Attach this line to the elbow fitting on the stainless coil
labeled “W”.

5. The remaining lines of the Multipar conduit are syrup

supply lines and must be attached to the appropriate
elbow fittings on stainless steel syrup coils. Note the
numbered lines attached to the opposite end of each
syrup coil when making connections.

Black Water

Supply Line

Braided CO

2

Gas Line

Color Coded

Syrup Lines

Water Supply & Regulator

CO2 Supply & Gauge

Insulated

Beverage