Section 5

Before Calling for Service

Part Number 020001552 5/11

5-1

Section 5

Before Calling for Service

Checklist

If a problem arises during operation of your post mix
soda refrigeration unit, follow the checklist below before
calling service. Routine adjustments and maintenance
procedures are not covered by the warranty.

!

Warning

Only trained and certified electrical and plumbing
technicians must service this unit. All wiring and
plumbing must conform to national and local codes.

Problem

Possible Cause

To Correct

Water only dispensing:

No pressure

Regulator(s) out of adjustment

Check/adjust regulator(s).

Out of CO

2

Install fresh tank.

Defective regulator(s)

Check/repair/replace regulator(s).

CO

2

line pinched, kinked, or obstructed

Check/repair/replace CO

2

line.

Syrup and CO

2

only dispensing:

Carbonator

No power

Check poser supply. Plug in carbonator

or reset breaker.

Water supply

Make sure water is turned ON.

Replace water filter.

Check/clean/replace pump strainer.

Check/clean/repair water check valve.

Check for frozen water line.

Internal Carbonator unit only.

Defective carbonator

Check/repair/replace carbonator pump,

motor, electrode or liquid level control.

Syrup and plain water only dispensing:

No pressure

Out of CO

2

Install fresh tank.

HP regulator out of adjustment

Adjust HP regulator to the proper setting.

Defective HP regulator

Check/repair/replace HP regulator.

CO

2

line pinched, kinked, or obstructed

Check/repair/replace CO

2

line.

One valve will not dispense anything:

Is there power to the valve?

Broken wire or loose connection

Replace/repair wire or connector.

Bad microswitch

Replace microswitch.

Beverage dispensed is too sweet:

Is the ratio (brix) of the drink correct?

Flow control out of adjustment

Adjust the flow control.

Insufficient soda flow due to low

carbonator pressure

Adjust CO

2

pressure or change the tank.

Low CO

2

pressure due to leaks

Repair CO

2

leaks.

Obstruction in the water or soda line

Clean out the lines.

Beverage is not sweet enough:

Is the ratio (brix) of the drink correct?

Flow control out of adjustment

Adjust the flow control.

Soda flow too high

Reset CO

2

pressure or replace regulator

if necessary.

Obstruction in syrup line

Clean out the syrup line.

Drinks are foaming:

Are system pressures correct?

Over carbonation

Check CO

2

supply. Reset pressure or

replace regulator is necessary.

Dirty lines/valves

Clean sanitize entire system.