Warning clearances – Monessen Hearth 6000DV User Manual

Page 14

Advertising
background image

14

42D0200

V

W

X
Y

Z

A B C D E

Follow these instructions carefully to ensure safe installation. Failure to follow
instructions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other
than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed
on a metal, wood or noncombustible material panel extending full width and depth of
the appliance.

W

ARNING

CLEARANCES

CLEARANCES TO COMBUSTIBLES

MANTEL CLEARANCES

NOTE: The combustible area above the facing must not protrude more than

3

/

4

" from the facing. If it does,

it is considered a mantel and must meet the mantel requirements listed in this manual.

Figure 11 - Clearances

Mantel Shelf Chart (Minimum Height)

Ref. Mantel Depth Ref. Height Above Louvres
V

10" (254mm)

A

12" (305mm)

W

8" (203mm)

B

10" (254mm)

X

6" (152mm)

C

8" (203mm)

Y

4" (101mm)

D

6" (152mm)

Z

2" (50mm)

E

4" (101mm)