REAR WALL VENT INSTALLATION

When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind

the appliance
• The maximum horizontal distance between the rear of the appliance and the outside face of the rear wall is 20" (508 m).

See Figure 19.

• Only one 45° elbow is allowed in these installations.

VENTING INSTALLATION

Note: Horizontal runs of vent
must be supported every three
feet (914mm). Use wall straps
for this purpose.

Figure 21 - Rigid Vent Pipe Connections

Female

Locking Lugs

Male Slots

Figure 20 - Vent Opening Requirements

1. Locate and cut the vent opening in the wall. For

combustible walls first frame in opening.

Combustible Walls:

Cut a 11

1

2

"H x 9

1

2

" W (292mm

x 24mm) hole through the exterior wall and frame as

shown. See Figure 20.

Noncombustible Walls:

Hole opening should be

7

1

2

" (190mm) in diameter.

2. Rigid vent pipes and fittings have special twist-lock

connections. Assemble the desired combination of

pipe and elbows to the appliance adaptor with pipe

seams oriented towards the wall or floor.

Twist-lock Procedure:

The female ends of the pipes

and fittings have three locking lugs (indentations).

These lugs will slide straight into matching slots on

the male end of adjacent pipes and fittings. Push the

pipe sections together and twist one section clockwise

approximately one-quarter turn until the sections are

fully locked. See Figure 21.