Pre-installation information – Monessen Hearth 6000DV User Manual

Page 6

Advertising
background image

6

42D0200

PRE-INSTALLATION INFORMATION

INSTALLING ABOVE 2000 FEET

• In the USA, the appliance must be derated 4% for every 1,000 ft above 2,000 ft elevations.
• In Canada, these appliances are certified for altitudes of 0 – 2000 ft, and must be de-rated by 10 percent for installations

between 2000 and 4,500 ft. (derate an additional 4% for every 1,000 ft. above 4,500 ft. elevations).

• Contact gas supplier.

ORIFICE SIZES, PRESSURES AND BTUs

NATURAL GAS

PROPANE GAS

Manifold Press: (W.C.)

3.5"

Manifold Press: (W.C.)

10"

Maximum Supply Pressure 10.5"

Maximum Supply Pressure

13"

Minimum Supply Pressure

4.5"

Minimum Supply Pressure

11"

Model Number

6000DV

NATURAL

PROPANE

Max. Btu/hr Input

36000

36000

Min. Btu/hr Input

25000

26000

Orifice size (as shipped)

#43

#54

BEFORE YOU INSTALL

Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and

immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts.

Check your packing list to verify that all listed parts have been received. You should have the following:
• Fireplace (Firebox and Burner System)

• Log Set

• Lava Rock

• Rock Wool

• Deflector Shield (to be used with Simpson DuaVent Horizontal Termination – P/N 985)
ITEMS REQUIRED FOR INSTALLATION
Tools:

Building Supplies:

• Phillips Screwdriver

• Framing Materials

• Hammer

• Wall Finishing Materials

• Saw and/or saber saw

• Caulking Material (Noncombustible)

• Level

• Fireplace Surround Material (Noncombustible)

• Measuring Tape

• Piping Complying with Local Codes

• Electric Drill and Bits

• Tee Joint

• Pliers

• Pipe Sealant Approved for use with Propane/LPG

• Square

(Resistant to Sulfur Compounds)

• Pipe Wrench

Advertising