24

42D0200

10'

7'6"

7'

A

B

• If a 90° elbow is used in the

horizontal vent run, the horizon-

tal vent length is reduced by 36"

(914 mm). See Figure 28. This

does not apply if the 90° elbows

are used to increase or redirect

a vertical rise. See Figure 29.

Example: According to the vent
graph, Figure 27, the maxi-
mum horizontal vent length in a
system with a 7.5' vertical rise
is 20’ (6m) and if a 90° elbow is
required in the horizontal vent it
must be reduced to 17' (5.2 m).
See page 22 “How to Use Vent
Graph.”
In Figures 28 and 29,

Dimension

A plus B must not be greater than

17' (5.2m).
• The maximum number of 45°

elbows permitted per side wall

installation is two (2). These

elbows can be installed in either the vertical or horizontal run.

• For each 45° elbow installed in the horizontal run, the length of the horizontal run

MUST be reduced by 18" (45cm). This does not apply if the 45° elbows are installed

on the vertical part of the vent system.

• The maximum number of elbow degrees in a system is 270°. See Figure 30.

Figure 29 - Maximum Vent Run with Elbows

Example:

Elbow 1 = 90°

Elbow 2 = 45°

Elbow 3 = 45°

Elbow 4 = 90°

Total Angular Variation = 270°

Figure 30 - Maximum Elbow Usage

VENT INSTALLATION

A + B = 17' Maximum

90° Elbow = 3'

1 + 2 + 3 + 4 = 270°

1
2
3
4

1
2
3
4

Figure 28 - Horizontal Run Reduction

90°

7'6"

A

B

40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10

8
6
4
2

2 4 6 8 10 1214 16 1820

eg: A

Figure 27 - Rear Wall

Venting Graph

Horizontal Dimension From the

Outside Face of the Wall to the

Center of the Fireplace Vent

Flange