VENT INSTALLATION

OPTIONAL TOP VENT APPLICATION

The appliance is shipped as a rear vent unit. If the installation

layout requires the unit to be a top vent configuration the appli-

ance can be converted by following the steps below.
When removing and refitting the plates and adapter be sure the

associated gaskets are undamaged and refitted as required.
1. Remove the eight (8) screws securing the flue pipe adapter

to the fireplace body. See Figure 13.

2. Set the flue pipe adapter aside, complete with the gasket.

Do not damage the gaskets as the adapter and gasket must

be refitted.

3. Remove the eight (8) screws securing the flue pipe cover to

the top of the intake box and remove the cover and gasket.

See Figure 13.

4. Remove eight (8) screws securing the flue pipe to the

back of the intake box and remove the pipe and gasket.

See Figure 14.

5. Replace flue pipe to top of firebox. Ensure the gasket is in

place and undamaged. Secure with eight (8) screws. See

Figure 15.

6. Place the flue pipe cover and gasket removed in step 3 over

the flue opening in bottom of the intake box.

7. Refit the flue pipe adapter and gasket to the top of fire-

place. Secure the adapter with eight (8) screws removed

in step 1.

A f t e r c o n v e r s i o n t o t o p v e n t
configuration the 4" (100mm) flue pipe
should be concentric within the 6

5

/

8

"

(175mm) outer collar (within

1

/

4

").

W

ARNING

Figure 13 - Removing sixteen (16) Screws from

Flue Pipe Adapter and Flue Pipe Cover

Figure 14 - Removing Flue Pipe

Figure 15 - Attaching Flue Pipe to Top

Vent Configurations

Screws

Flue Pipe

Cover

Flue Pipe

Adapter

Flue

Cover

Flue Pipe

Screws

Flue Pipe

Screws