background image

Chapter 3 – Related MultiVOIP Setup Parameters

44

Multi-Tech Systems, Inc. Avaya Communication Manager Guide

FXS Loop Start Parameters. The parameters applicable to FXS Loop Start are shown in the figure below

and described in the table that follows.

FXS Loop Start Interface: Parameter Definitions

Field Name

Values

Description

FXS (Loop
Start)

Y/N

Enables FXS Loop Start interface type.

Dialing Options

fields

Inter Digit
Timer

1 - 10 seconds

This is the length of time that the MultiVOIP will wait between
digits. When the time expires, the MultiVOIP will place the call.
Default = 2.

Message
Waiting
Indication

--

If “Register with Communication is enabled”, this field enables
message waiting indication on FXS channels. Choices are “Light” or
“Stutter Dial Tone”.

Inter Digit
Regeneration
Time

in milliseconds

The length of time between the outputting of DTMF digits.
Default = 100 ms.

Ring Count,
FXS

1-99

Maximum number of rings that the MultiVOIP will issue before
giving up the attempted call.

FXS Options,
Current Loss

Y/N

When enabled, the MultiVOIP will interrupt loop current in the FXS
circuit to initiate a disconnection. This tells the device connected to
the FXS port to hang up. The Multi-VOIP cannot drop the call; the
FXS device must go on hook.