background image

Canopy  T1/E1 Multiplexer 

 

 

 

 

 

 

September 2004 

 

 

 

 

 

 

     

      T1/E1 Multiplexer FPGA Version 3.4 


Page 30 of 73 

Canopy BH
RJ-45
connector

Pin

LAN

RJ-45
connector

Color

TD+ 1

TD+ White/Green

TD- 2

TD- Green

RD+ 3

RD+ White/Orange

Nc 4

Not

used

Blue

Nc 5

Not

used

White/blue

RD 6

RD Orange

Nc 7

Not

used

White/brown

Nc 8

Not

used

brown

Figure 12: RJ-45 Ethernet connection pin-outs (LAN side)

Perform this procedure to connect the cables to the T1/E1 unit.

Procedure 2: Connecting cables to T1/E1 unit

1. Connect the T1/E1 cables to the T1/E1 ports.

NOTE: There is a one-to-one relationship between the T1/E1 ports on the
Canopy T1/E1 Multiplexer. This means, that the T1/E1 cable connected to the
T1/E1 Port 1 on one of the Canopy T1/E1 Multiplexers, must also be connected
to Port 1 on the other.

2. Connect the Ethernet cables to the Ethernet ports.

3. Connect the power cable to the power connector.

end of procedure

2.2.5 Connecting Power to the Canopy T1/E1 Multiplexer 

The Canopy T1/E1 Multiplexer is available in two power configurations:

an external 3.3-v DC power source (supplied by Canopy)

◦ an

external

−48 v DC power supply with a terminal strip that plugs into the back

of the Canopy T1/E1 Multiplexer.

Issue 3

 

Advertising