Motorola T1/E1 User Manual

Page 41

Advertising
background image

Canopy  T1/E1 Multiplexer 

 

 

 

 

 

 

September 2004 

 

 

 

 

 

 

     

      T1/E1 Multiplexer FPGA Version 3.4 


Page 41 of 73 

Action Steps

Set timing mode

NOTE: Timing mode applies to all four T1 lines. Loopback mode loops the
T1/E1 Tx clock to the T1/E1 Rx. Recovered mode recovers the T1/E1 clock
from the incoming T1/E1 over Ethernet bit stream (recovers the clock from
the far end T1/E1). The default timing mode is Recovered.

Enter set clock source [loopback/recovered]

where

[loopback/recovered]

represents the clock timing mode.

RESULT: The system responds

Clock source is [loopback/recovered]

Set master clock
reference line

NOTE: This is the master clock reference for all four T1/E1 lines.
The default setting is T1/E1 Port 1.

Enter set master clock reference line [1/2/3/4]

where

[1/2/3/4]

represents T1/E1 ports 1 through 4.

RESULT: The system responds

Clk ref line; [1,2,3,4]

Set backup clock
reference line

NOTE: This is the optional backup clock reference for all four T1/E1 lines.
The backup clock reference becomes active only when the master clock
reference line is unavailable. The default setting is T1/E1 Port 2.

Enter set secondary clock reference line [1/2/3/4]

where

[1/2/3/4]

represents T1/E1 ports 1 through 4.

RESULT: The system responds

Backup clk ref line; [1/2/3/4]

Log off

Enter lo.
RESULT: The system responds goodbye.

end of procedure

Issue 3

 

Advertising