3.2 T1/E1 ALARMS 

Each T1/E1 channel has alarms for line code violation (BPV), receive loss of signal
(LOS), and alarm indication signal (AIS) detection.

Follow these steps to display the alarms using the CLI.

Procedure 23: Displaying the alarms using the CLI

Action Steps

Log in

Press Enter.

At the username prompt, enter admin.

At the password prompt, enter password.

View T1/E1 Alarms

Enter get alarms.

The system responds displays alarms for all 4 T1/E1 ports, as in the
following example:

Line1:

Line code violation: No

Receive Loss of Signal: No

Alarm Indication Signal Detect: No

Line2:

Line code violation: No

Receive Loss of Signal: No

Alarm Indication Signal Detect: No

Line3:

Line code violation: No

Receive Loss of Signal: No

Alarm Indication Signal Detect: No

Line4:

Line code violation: No

Receive Loss of Signal: No

Alarm Indication Signal Detect: No

FPGA: 00

Log off

Enter lo.
RESULT: The system responds goodbye.