Configuration procedures using the ems, Logging into the system, Procedure 14: logging in using the ems – Motorola T1/E1 User Manual

Page 45

Advertising
background image

Canopy  T1/E1 Multiplexer 

 

 

 

 

 

 

September 2004 

 

 

 

 

 

 

     

      T1/E1 Multiplexer FPGA Version 3.4 


Page 45 of 73 

Action Steps

Set timing mode

NOTE: Timing mode applies to all four E1 lines. Loopback mode loops the T1/E1
Tx clock to the T1/E1 Rx. Recovered mode recovers the T1/E1 clock from the
incoming T1/E1 over Ethernet bit stream (recovers the clock from the far end
T1/E1). The default timing mode is Recovered.

For master clock timing mode, enter
set clock source loopback

RESULT: The system responds

Clock source is loopback

For slave clock timing mode, enter
set clock source recovered

RESULT: The system responds

Clock source is recovered

Log off

Enter lo.
RESULT: The system responds goodbye.

end of procedure

2.5 CONFIGURATION PROCEDURES USING THE EMS 

2.5.1 Logging into the System 

Procedure 14: Logging in using the EMS

If you are using the EMS to access the system, follow the steps below to log in:

1. Select the proper COM Port for your PC.

NOTE: COM1 through COM4 are supported.

2. Enter

the

User Name.

NOTE: The default username is admin. This value cannot be changed.

3. Enter

the

Password.

NOTE: The default password is 123. If the password has been changed, enter
the correct password.

4. Select

the

Login button to continue with the login.

NOTE: If the login is unsuccessful, the system will generate a pop-up error
window. You may return to the Login window to correct the data.

Issue 3

 