INSTALLATION

12

Figure 7

Hot Water Connection

(MH-60 Only)

3/4" NPT

Figure 8

Hot Water Connection

(MH-6N, MH-6L Only)

3/4" NPT

INSTALLATION

(Cont.)

Plumbing Connections

NOTE:

Plumbing connections must comply with
all applicable sanitary and plumbing
codes.

Water Connections

1. All MH series dishwashers require a single,

hot water supply.

The hot water connection to all MH
series dishwashers is 3/4" NPT.

The connection is made from
underneath the dishwasher.

The following minimum water
temperatures are recommended:

MH-60 with built-in 40

° rise electric

booster (Minimum 140

°F/60°C)

(Min./Max. flow pressure
20-22 PSI/138-151.8 kPa)

MH-60 with built-in 70

° rise electric

booster (Minimum 110

°F/43°C)

(Min./Max. flow pressure
20-22 PSI/138-151.8 kPa)

MH-6N without built-in booster
(Minimum 180

°F/70°C)

(Min./Max. flow pressure
20-22 PSI/138-151.8 kPa)

MH-6L low temperature
(Minimum 120

°

F/49

°

C-

140

°

F/60

°

C Optimum)

(Min./Max. flow pressure
20-22 PSI/138-151.8 kPa)

Refer to Figs. 7 and 8