TROUBLESHOOTING

25

TROUBLESHOOTING

Perform the seven checks listed below in the event that your dishwasher does not operate
as expected.

1. All switches are ON
2. Drain-overflow assemby is in place and seated
3. Wash and rinse nozzles are clean
4. Wash and rinse pipe assemblies are installed correctly
5. Scrap screens are properly positioned
6. Thermostat(s) are properly adjusted
7. Detergent and rinse additive dispensers are adequately filled

If a problem still exists, use the following table for troubleshooting

CONDITION

CAUSE

SOLUTION

Machine will not start

Doors not closed ...................................

Make sure doors are fully closed

Door safety switch faulty ......................

Contact your service agency

Start switch faulty .................................

Contact your service agency

Main switch off .....................................

Check disconnect at main panel

Overload protector tripped ...................

Reset overload in Control Box

Machine washes

Extended wash switch in .......................

Push Extended wash switch

constantly

extended wash position

down to the off position

Low or no water

Main water supply is turned off ............

Turn on house water supply

Drain-overflow assembly is not ............

Place and seat drain-overflow

in place and seated
Machine doors not fully closed .............

Close doors securely

Faulty fill valve .....................................

Contact your service agency

Machine not filled initially ...................

Push Power switch UP to fill

Clogged strainer in fill valve ................

Clean or replace

Continuous water filling

Stuck or defective Fill Timer ................

Contact your service agency

Fill valve will not close .........................

Clean or replace

Drain-overflow not in place ..................

Install drain-overflow assembly

Wash motor not running

Overload protector tripped ....................

Reset overload in Control Box

Defective motor ....................................

Contact your service agency

Wash tank water

Incoming water temperature .................

Raise temperature to:

temperature is low

at machine too low

110-140

°F/43-60°C for MH60

when in use

180

°F/82°C for MH-6N

120

°F/49°C-140°F/60°C for MH6L

Defective thermometer

Check or replace

Defective thermostat .............................

Check for proper setting
or replace

Defective heater element ......................

Check or replace

Defective solenoid valve .......................

Check or replace

Heater elements .....................................

Clean and delime

have soil/lime buildup

Advertising