Electrical service (cont.), Motor overloads – Moyer Diebel MH-6NM2 User Manual

Page 30

Advertising
background image

BASIC SERVICE

28

ELECTRICAL SERVICE (Cont.)

Fuses —

Refer to Fig. 14.
There are two fuse blocks, located in the
main control cabinet. The (A) fuses
protect the control circuit. The (B) fuses
protect the wash tank heater circuit.
Booster heater circuits (MH-60 only)
are not fused.

To Replace a fuse:
Turn the dishwasher main power switch
off. Disconnect power to the machine at
the main servicedisconnect switch.
Replace the fuse. If the fuse blows again,
DO NOT INCREASE THE FUSE SIZE.
DETERMINE THE CAUSE OF THE OVERLOAD.

Motor Overloads —

The wash pump motor has an overload to protect it from line
voltage electrical overloads. The overload disconnects
220VAC power to the motor contactor coil.

Refer to Fig. 15.

Note the Switch Lever on the Overload.
If the switch lever is off with the “0” showing
then the overload has tripped.

To Reset the Motor Overload:
Flip the overload switch to the On position.
A “1” should be visible on the switch lever.

To Replace a Motor Overload:
Disconnect the wires to the overload.
Release the mounting catch on the front
side of the overload. Push forward and lift out.
Snap the new overload into place and reconnect
the wires.

To adjust the overload setting:
The screwdriver in Fig. 15 is positioned
to adjust the motor overload AMP setting.
Read the full load amps (FLA) motor amps on the motor
nameplate. Adjust the overload dial to 125% of the name-
plate FLA or the maximum setting.

Figure 15

Motor Overload

Switch Lever

Figure 14

Fuses

(Three phase shown)

B

A

Advertising
This manual is related to the following products: