INSTALLATION

15

Chemical Connections (Cont.)

Refer to Fig. 12

5. A 1/2" NPT detergent probe injection point

is provided at the rear of the dishwasher.

6. Detergent may be added manually if your

dishwasher is not equipped with
dispensing equipment. Consult your
chemical supplier for recommended
amounts.

Refer to Fig. 13

7. A 1/8" NPT rinse aid injection point is

provided in the final rinse manifold.
Use a liquid rinse aid.
The manifold is located on the top right
side of the dishwasher.

8. MH-6L Only

A 1/4" NPT sanitizer injection point is
provided in the final rinse manifold.

Models MH-60 and MH-6N do not
require sanitizer.

9. Use a sodium hypochlorite (Chlorine)

based sanitizer at a minimum concentration
of 50PPM in the final rinse.

10. Use chlorine test papers to verify and

monitor the 50PPM chlorine level.

WARNING:

Never premix rinse aid with the
sanitizing agent. Mixing may cause
hazardous gases to form.

CAUTION:

Some metal, includng silver, aluminum
and pewter are attacked by sodium
hypochlorinte (chlorine). Avoid cleaning
these metals in a MH-6L.

Figure 12

Detergent Probe Injection Point

1/2" NPT

(Wash Tank Rear)

Figure 13

Rinse Aid and

Sanitizer Injection Points

(Top of Dishwasher)

!

!

1/4" NPT Sanitizer
Injection Point
Model MH-6L Only

1/8" NPT Rinse aid Injection Point
Models MH-60, MH-6N, MH-6L

Advertising