4 at commands, s-registers, and result codes, Multimodemzpx user guide – Multi-Tech Systems MT5634ZPX-PCI-V92 User Manual

Page 32

Advertising
background image

4 AT Commands, S-Registers, and Result Codes

27

MultiModemZPX User Guide

Command:

&D

n Data Terminal Ready (DTR) Control

Values:

n = 0, 1, 2, or 3

Default:

2

Description:

&D0 Modem ignores the true status of the DTR signal and responds

as if it is always on.

&D1 If DTR drops while in online data mode, the modem enters

command mode, issues an OK, and remains connected.

&D2 If DTR drops while in online data mode, the modem hangs up.

If the signal is not present, the modem will not answer or dial.

&D3 If DTR drops, the modem hangs up and resets as if an ATZ

command were issued.

Command:

&E

n

XON/XOFF Pacing Control

Values:

n = 12 or 13

Default:

12

Description:

&E12 Disables XON/XOFF pacing.
&E13 Enables XON/XOFF pacing. (&K4 must also be set.)

Note:

&E13 has no effect if hardware control (&K3) is selected.

Command:

&F

n

Load Factory Settings

Values:

n = 0

Default:

None

Description:

&F0

Loads factory settings as active configuration.

Note:

See also the Z command.

Command:

&G

n V.22bis Guard Tone Control

Values:

n = 0, 1, or 2

Default:

0

Description:

&G0 Disables guard tone.
&G1 Sets guard tone to 550 Hz.
&G2 Sets guard tone to 1800 Hz.

Note:

The &G command is not used in North America.

Command:

&K

n Flow Control Selection

Values:

n = 0, 3, or 4

Defaults:

3

Description:

&K0 Disables flow control.
&K3 Enables CTS/RTS hardware flow control.
&K4 Enables XON/XOFF software flow control.

Command:

&Q

n Asynchronous Communications Mode

Values:

n = 0, 5, 6, 8, or 9

Default:

5

Description:

&Q0 Asynchronous with data buffering. Same as \N0.
&Q5 Error control with data buffering. Same as \N3.
&Q6 Asynchronous with data buffering. Same as \N0.
&Q8 MNP error control mode. If MNP error control is not estab-

lished, the modem falls back according to the setting in S36.

&Q9 V.42 or MNP error control mode. If neither error control is es-

tablished, the modem falls back according to the setting in S36.

Advertising