4 AT Commands, S-Registers, and Result Codes

40

MultiModemZPX User Guide

S-Registers

Certain modem values, or parameters, are stored in memory locations called S-registers.
Use the S command to read or to alter the contents of S-registers (see previous section).

Register Unit

Range

Default

Description

S0

1 ring

0, 1–255

0

Sets the number of rings until the modem
answers. ATS0=0 disables autoanswer com-
pletely. Range varies by country. Set S0=2
for Caller ID.

S1

1 ring

0–255

0

Counts the rings that have occurred.

S2

decimal 0–255

43 (+)

Sets ASCII code for the escape sequence char-
acter. Values greater than 127 disable escape.

S3

decimal 0–127

13 (^M) Sets the ASCII code for the carriage return

character.

S4

decimal 0–127

10 (^J)

Sets the ASCII code for the line feed character.

S5

decimal 0–32,

8 (^H)

Sets the ASCII code for the backspace char-

33–127

acter. Values over 32 disable backspace.

S6

seconds 2–65*

2*

Sets the time the modem waits after it goes
off-hook before it begins to dial the telephone
number.

S7

seconds 1–255*

50*

Sets the time the modem waits for a carrier
signal before aborting a call. Also sets the
wait-for-silence time for the @ dial modifier.

S8

seconds 2–65

2

Sets the length of a pause caused by a comma
character in a dialing command.

S9

decimal 0, 1–127

37 (%)

Sets ASCII code for remote configuration
escape character. S9=0 disables remote
configuration.

S10

100 ms

20–255

20

Sets how long a carrier signal must be lost
before the modem disconnects.

S11

1 ms

50–150*

95*

Sets spacing and duration of dialing tones.

S28

decimal 0, 1–255

1

0 disables, 1–255 enables V.34 modulation.

S30

1 minute 0, 1–255

0

Sets the time the modem waits before it dis-
connects when no data is sent or received. A
value of zero disables the timer. See also the
\T

command

S35

decimal 0–1

0

0 disables, 1 enables the V.25 data calling
tone, which allows remote data/fax/voice
discrimination.

S36

decimal 0–7

7

Specifies the action to take in the event of a
negotiation failure when error control is se-
lected. See S48.

* These values may be different outside North America.