USER GUIDE

48

Note! Picture quality is relative to distance. The further away a remote computer is
from the Smart 108/116 IP, the lower the image quality, and the more tuning
needed. So place the higher resolution computers closer to the Switch.

25.12 Moving the label – F6

Position the Confirmation label anywhere on the screen.

To position the label from the Main window:

1. Navigate to the desired computer using the Up and Down arrow keys.

2. Press F6. The selected screen image and Identification label will appear.

3. Use the arrow keys to move the label to the desired position.

4. Press Esc to save and exit.

25.13 DDC – F10

Display Data Channel (DDC) is a VESA standard for communication between a
monitor and a video adapter.

Input the DDC information of the monitor connected to the Smart 108/116 IP
switch into the memories of all connected ROC/RICCs when first installing
system.

To input the DDC information:

1. Disconnect the Video cable of all RICCs from the computers. ROCs do not

need to be disconnected.

2. Press Shift twice to open the OSD.

3. Press F10. “Please wait” flashes a few times and disappears. The monitor’s

DDC information is sent to all ROC/RICCs.

4. Reconnect the Video cable of all RICCs.

25.13.1.1 Updating the DDC information

Update the DDC information in any of the following circumstances:

· When replacing the monitor connected to Smart 108/116 IP Switch
· When adding a new ROC/RICC to the system
· When reconnecting an existing ROC/RICC that was temporarily used in a

different system

To update the DDC information, repeat the steps as set out above.

Advertising