27. Update software - Troubleshooting

This section covers:

· Communication Error message
· Electricity failure

27.1 Communication Error message

When updating a unit and a Communication Error message appears, do the
following:

1. Check that the RS232 Serial cable’s RS232 connector is connected to the

Switch’s Flash port.

2. Check that the RS232 Serial cable’s DB9F connector is connected to the

laptop’s Serial port.

3. Verify there is no Remote session in progress by pressing the Local button.

4. Restart the update process.

27.2 Electricity failure

When the electricity fails while updating the Smart 108/116 IP firmware, do the
following:

If the electricity fails during the firmware update of the Switch, a Communication
Error
message appears. Simply resume the firmware update by opening the folder
that contains the firmware update file and continue from there.

If the electricity fails during the firmware update of the RICCs a Not Responding
or Upgrade Error message appears. Restart the upgrade from the beginning.

(For electricity failure during a firmware upgrade of the digital part of the Smart
108/116 IP, see page 31).