Appendix 1: snmp events table, The table below lists all events recorded – Minicom Advanced Systems Minicom Smart 116 IP User Manual

Page 60

Advertising
background image

SMART 108/116 IP

59

Appendix 1: SNMP Events table

The table below lists all events recorded.

Event Text

Code Comment

"System Boot" 1010 Reported upon device boot up.

"Server Busy ask
for disconnect..."

1030 Attempt to connect when another user is already connected. The 2

nd

user has

permission for takeover, sent before the 2

nd

user actually takes over the

session.

"User login
succeeded"

1040 On every successful user login to the device.

"Login failed
wrong user
name or
password"

1050 Login failed due to wrong user name or password.

"Login not
succeeded
server busy"

1060 Login denied since a user with higher permission is connected (takeover not

allowed).

"Logout"

1070 User Logout (end of remote access session).

"Disconnected
by another user"

1110 Takeover has been successfully performed; the previous user has been

disconnected.

"Hardware
Failure"

1200 Device internal hardware failure. Try disconnecting any other attached device

and re-boot. If problem persists contact technical support.

"Hard reset
power cycle
command"

1220 Power cycle command issued, only relevant when a special power-cycle

product is attached to the device (e.g., KBPower).

"Viewer login"

1230 User connected in view-only mode (while another user is connected in a

regular session).

"Viewer logout" 1240 User connected in view-only mode has disconnected.

"Global access
disabled "

1250 Device has been blocked for access by an administrator; remote access is

disabled until the device is unblocked.

“Block User
Account”

1260 User blocked due to too many login attempts failure per policy in

configuration.

Successful User
Login

2010 Successful User Login CONF_USER_EVENT_LOGIN_SUCCEEDED

Login is not
successful –
wrong user
access level.

2020 Login is not successful – wrong user access level.

CONF_USER_EVENT_LOGIN_NOT_SUCCEEDED_WRONG_LEVEL

Wrong user
name or
password

2030 Wrong user name or password. Login is not successful.

CONF_USER_EVENT_LOGIN_NOT_SUCCEEDED_WRONG_USER_NAME_OR_PASSWOR
D

Advertising